Industrial optical communication solutions from TOMOR
Custom networking and fiber solutions for industry

Real Time Spectrometer

Browse technical resources about industrial optical communication, fiber switches, Ethernet over fiber, and networking solutions.

  • Adjustable Splitting Rate Spectrometer

    Adjustable Splitting Rate Spectrometer

    Fluid resistor technology eliminates adjustments to capillary tubing for optimizing split ratio. Wide range of interchangeable resistors available. Split ratio not affected by changes in viscosity or. ASI has developed a new design of Adjustable Flow Splitter, which is the 610 series. The 610 series splitters provide ASI customers with extended dynamic range, precise split setting and reduced dead volume. In particular, the Vernier scale feature enables the users to set splits reproducibly and. The Adjustable Makeup-Flow Splitter can be used to maintain a constant split flow over an inlet flow rate range (select "Variable Prep Inlet Flow and Fixed Split Flow" from the left menu). Dead volume on the low flow side is as low as 5 nL.


  • Namibia Spectrometer EDX720

    Namibia Spectrometer EDX720

    The EDX-7200 spectrometer provides high-precision quantitative and qualitative analysis of elements in the range from Na (11) to U (92) thanks to the use of an advanced silicon drift detector (SDD). The EDX-7200 is a flagship model of the EDX series in pursuit of high sensitivity, high speed and high precision. This model supports new regulations and directives for consumer and environmental compliance, such as RoHS/ELV, REACH, and TSCA with full exclusive screening analysis kits. Improved algorithms and improved performance also help to reduce measurement times., temperature fluctuation range: 10 ℃ max. ) Premium models with more durable X-ray tube windows. Microsoft ® Office is not included. Vacuum measurement unit (optional) consists of a control switch box and rotary pump. Compared to previous models, the counting speed is increased by up to 30 times, which allows you to. The EDX-720 is the most optimum tool for the rapid analysis of hazardous substances regulated by RoHS and ELV.

    [PDF Version]
  • Relay protection time limit difference

    Relay protection time limit difference

    The various protective functions available on a given relay are denoted by standard. For example, a relay including function 51 would be a timed overcurrent protective relay. An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay.


  • Delivery time for anti-tracking dense wavelength division multiplexer

    Delivery time for anti-tracking dense wavelength division multiplexer

    Dense wavelength-division multiplexing (DWDM) refers originally to optical signals multiplexed within the 1550 nm band so as to leverage the capabilities (and cost) of EDFAs, which are effective for wavelengths between approximately 1525–1565 nm (), or 1570–1610 nm (). EDFAs were originally developed to replace optical-electrical-optical (OEO), which they have made pra.


  • What does HFT mean in Optical Time Domain Reflectometer

    What does HFT mean in Optical Time Domain Reflectometer

    A TDR measures reflections along a conductor. In order to measure those reflections, the TDR will transmit an incident signal onto the conductor and listen for its. If the conductor is of a uniform and is properly, then there will be no reflections and the remaining incident signal will be absorbed at the far-end by the termination. Instead, if there are impedance variations, then some of the incident signal will be reflected back to the source. A TDR is similar in principle to.


  • Tr600 Optical Time Domain Reflectometer Card

    Tr600 Optical Time Domain Reflectometer Card

    The G-LINK TR600 Series OTDR is a high-performance, portable instrument engineered to meet the comprehensive measurement needs of FTTx, Metropolitan Area Networks (MAN), and Backbone Networks. With its compact, lightweight, yet rugged design, the TR600 is an indispensable tool for optical cable. Below you will find brief information for Optical Time Domain Reflectometer TR600 OTDR. It allows you to measure fiber length, attenuation, and identify faults by analyzing the reflected light signal. Intelligent testing, simple use, powerful function. Media of Memory Card + SD card, with superlarge storage capacity. The G-Link TR600 OTDR (Optical Time-Domain Reflectometer) is specifically engineered for professional fiber optic diagnostics.


  • How to connect the power cord to a spectrometer

    How to connect the power cord to a spectrometer

    Connect the female end of the power cord to the receptacle on the rear panel of the mass spectrometer. Not able to find a solution? Click here to request help. Remove components in order: fiber optic cable, handheld probe, adapter, power cable, Type-B data cable. Connection &. To supply power to the spectrometer, connect the DC power plug to the DC Power port on the back of the instrument. Identify the correct orientation of the DC plug. This manual provides users with directions for configuring your AvaSpec with your computer and operating of Quick Start. 0/Ethernet platform accessories. There is a separate manual for AvaSoft version. Quick and easy FTIR Spectrometer installation guide: Learn how to install your FTIR spectrometer with this step-by-step training video.