Industrial optical communication solutions from TOMOR
Custom networking and fiber solutions for industry

How We Deliver Electricity

Browse technical resources about industrial optical communication, fiber switches, Ethernet over fiber, and networking solutions.

  • How many access ports does the switch need

    How many access ports does the switch need

    How many ports do I need on a network switch? Count all wired devices, add 1-2 uplink ports, then add 20-30% for growth. Use the calculator above for precise. Switch ports are Layer 2 interfaces that are used to carry layer 2 traffic. Frames are handled differently according to the type of link they are traversing. Network switches are available with a diverse range of port. This calculator helps you determine exactly how many ports you need before you shop. The right choice depends on your network complexity and security requirements: If you're planning to separate IoT. Meraki's MS switches allow for the configuration of a single port to thousands of ports through our industry-first Virtual Stacking technology. Virtual Stacking provides centralized management of switch ports. RJ45 ports remain essential for.

    [PDF Version]
  • How to Choose Huawei Core Switches

    How to Choose Huawei Core Switches

    This article provides an in-depth guide to core switch selection, recommending models like the Huawei S6730 Series for businesses of varying sizes (50/500 employees). A Huawei 48-port switch is a fixed-configuration Ethernet switching platform offering exactly 48 physical RJ45 or SFP-based interfaces—designed primarily for wired endpoint connectivity in structured cabling environments. Unlike modular chassis switches, these are purpose-built for predictable. What exactly is a core switch? To use an analogy, it's like a city traffic command center, where the company's data traffic is diverted and forwarded. WeChat messages can be reached in seconds, surveillance videos are not stuck, and the ERP system is as stable as a dog, all of which depends on its. Huawei, a global leader in information and communication technology (ICT), provides a comprehensive range of network switches designed to meet the needs of businesses of every size - from small offices to hyperscale data centers.

    [PDF Version]
  • How to choose the thickness of fiber optic pigtails

    How to choose the thickness of fiber optic pigtails

    Single mode fiber pigtails use 9/125 µm fiber, typically with a yellow jacket. These are ideal for long-distance, high-bandwidth transmission and are widely used in telecom and WAN applications. The bare end is fusion-spliced to a trunk or distribution cable inside a splice tray or fiber distribution box. Common types include single-mode OS2, multimode OM3/OM4. Executive Summary: A fiber optic pigtail is one of the most commonly specified yet least understood components in structured cabling. Get the wrong connector type, the wrong polish, or skip proper fusion splicing technique—and you're looking at elevated signal loss, increased back reflection, and a. Today, I'll show you how to pick the right patch cord or pigtail — step by step. A Fiber Patch cord connects two devices. You plug it into a switch, router, or patch panel. Fiber optic pigtails are used to terminated fiber optic cables via fusion splicing or mechanical splicing as shown in the picture. The fiber pigtails are designed to support fusion and mechanical splicing for fiber cabling systems.

    [PDF Version]
  • How to determine the quality of wiring in a distribution box

    How to determine the quality of wiring in a distribution box

    Practice good wiring: secure grounding, neat cable management, proper insulation, and correct wire gauge and breaker size. Include protection devices like breakers, fuses, and surge protectors—each circuit should have its own protection. Check for proper IP/NEMA ratings and material quality. Ensure safe placement: install in. Use this Electrical Quality Control Checklist as a template to conduct QA of wiring, connections, installations, and electrical safety measures. Are all electrical works being performed according to site-specific safety regulations? 2. Is proper PPE (gloves, insulated tools, boots) available and. The checklists are intended to help inspectors keep track of the numerous aspects of an electrical installation that must be checked, verified, reviewed, determined, or otherwise examined for NEC ® compliance. Look for any signs of burnt or damaged wiring. Testing Test the grounding system.

    [PDF Version]
  • How much does a meter of wire mesh cable tray cost in Bhutan

    How much does a meter of wire mesh cable tray cost in Bhutan

    Pricing and Offer: Prices range from $0. 00 per meter, with higher costs for stainless steel (SS304/SS316) or powder-coated variants. Competitors: Panduit, Snake Tray, nVent (Hoffman), and Niedax Group. FortunebusinessinsightsThe average cable tray price per meter ranges from $2 to $25, depending on material, type, size, and surface finish. 👉 For bulk orders or project pricing, the cost can be significantly lower. It is relatively affordable, especially when considering its durability and long lifespan. Additionally, it requires minimal maintenance, reducing ongoing costs. Cable trays will tend to be significantly less expensive to use in 2026 than metal pipes due to their faster installation. We want to improve this website so we need your help. Please send us your recommendations, suggestion, and request.

    [PDF Version]
  • How many dBm of loss does a 12-splitter lose

    How many dBm of loss does a 12-splitter lose

    A splitter will have approximately 3. 5 dB of loss on each port. Let's say you have a laser output at 0 dBm (which is 1 milliwatt of optical power). Review watts, dBm, voltage, and isolation quickly. Use equal mode for identical outputs. A signal output from a. Every time you double the ports, you double the signal paths — and the theoretical loss grows by about 3 dB. Enter the number of outputs and the excess loss from your splitter datasheet to see the total insertion loss. Typical PON values are 2, 4, 8, 16, 32, 64. Design passive splitter cascades for GPON, XGS-PON, and EPON systems. in Watts – W), the loss value in dB is calculated by the formula: Loss (dB) = 10 lg ( mW1 / mW2 ) When both gains are equal, the loss is 0 dB, so there is no loss (doesn't happen obviously).

    [PDF Version]
  • How to tie cables with a cable management rack

    How to tie cables with a cable management rack

    Using cable management accessories like D-rings, vertical organizers, and cable trays can help secure cables and guide them neatly along the rack. As businesses increasingly rely on robust network infrastructure, proper cable organization becomes critical for. Master your server room cable management setup with our pro guide—boost efficiency, prevent downtime, and ensure compliance for your IT operations. Need a site survey? Talk to a cabling team that works in NYC buildings every day. Modern network racks face new physical constraints: deeper switches, hotter PoE++ loads, and thicker Cat6A cabling. A standard 48-port PoE++ switch now. Docusnap automatically documents and visualizes cable flows - ideal for efficient, legally compliant IT & network rack cable management. Without a well-thought-out system for routing, labeling. The goal of server rack cable management is to create a clean and organized setup that minimizes cable clutter, reduces the risk of accidental disconnections, and enables efficient troubleshooting.

    [PDF Version]
  • How to lay a 35 kV power fiber optic cable

    How to lay a 35 kV power fiber optic cable

    This document provides procedures for installing OPGW fiber optic cables on transmission lines between 35kV and 400kV. It outlines the planning, installation, splicing and testing processes. Special care must be taken to avoid damaging the optical fibers during installation by observing minimum. Installing ADSS (All-Dielectric Self-Supporting) cables near live power lines demands precision, compliance with safety standards, and an understanding of high-voltage risks. This guide from GL FIBER breaks down the process into actionable steps, aligned with IEEE 524 and IEC 61935-1 protocols, to. The practices contained herein are designed as a guide. The recommended practices are based on average conditions. In extreme cold climates, cables may need to be buried at greater depths where there temperatures are colder and frost penetrates to.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +49 69 2381 5497
Address Am Hauptbahnhof 10, 60329 Frankfurt am Main, Germany

Send an Inquiry