Industrial optical communication solutions from TOMOR
Custom networking and fiber solutions for industry

Everything You Need To Know About 25g Optics

Browse technical resources about industrial optical communication, fiber switches, Ethernet over fiber, and networking solutions.

  • Venezuela Polarization-Maintaining Fiber Optics G 652D

    Venezuela Polarization-Maintaining Fiber Optics G 652D

    Polarization-maintaining fibers work by intentionally introducing a systematic linear in the fiber, so that there are two well defined polarization modes which propagate along the fiber with very distinct phase velocities. The beat length Lb of such a fiber (for a particular wavelength) is the distance (typically a few millimeters) over which the wave in one mode will experience an additional delay of one wavelength compared to the other polarization mode. Thus a length Lb /2 of such fiber is equivalent to a.


  • Do relay protection systems need to be calibrated annually

    Do relay protection systems need to be calibrated annually

    110 (4), ER (Electricity Regulations) 1994; any protective relay and device of an installation will need to be checked, tested and calibrated by a competent person at least once every two years, or at any time as directed by the Energy Commission. Why is protective relay testing. Settings of various relays need co-ordination. Tests are conducted by the manufacturer at manufacturer s works, and by the user at site during commissioning and periodic maintenance. Many operators carry out secondary injection annually to ensure relays that protect circuits against overloads or faults operate appropriately. If applicable, documentation is required detailing how verified protection segments overlap to ensure there is not a gap. A relay may only need to operate for a fraction of a second in its decades-long life, but that moment can prevent extensive damage, prolonged outages, and worker injury.

    [PDF Version]
  • Do data center PDUs need lightning protection

    Do data center PDUs need lightning protection

    If your equipment is sensitive to voltage fluctuations or installed in environments exposed to lightning, switching surges, or industrial electrical interference, a PDU with surge protection is recommended. Especially in data centers, lightning protection PDUs are a key tool to ensure stable operation of equipment. Data centres form the backbone of our digital infrastructure, yet they face significant risks from lightning strikes and power surges. In the Netherlands alone, around 300,000 lightning strikes are recorded. Many data center managers assume that power distribution units (PDUs), especially rack-mounted PDUs, automatically protect servers from voltage spikes. A single lightning strike or utility power surge can damage critical equipment, disrupt operations, and lead to. Based on the principle that 'prevention is better than cure' it is advisable to think about the protection of your data centre against the risk of lightning strikes.

    [PDF Version]
  • Do horizontal cable trays need cover plates

    Do horizontal cable trays need cover plates

    Due to their exposure to the open air because of the cable trays, the wires contained within need a very durable outer covering. The regulations dictate that the cables must either be Type TC (also known as Tray Rated) or must be metal-armored (Type MC). Here's what you need to know: Cable Types: Only use. The short answer is no. These essential components: Example:. This guide covers the critical steps, from selecting the right electrical cable tray and performing accurate cable fill calculations to managing a safe cable pull through and ensuring all bonding and grounding requirements are met. For licensed electricians, mastering these principles is essential. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions.

    [PDF Version]
  • Do galvanized wire mesh cable trays need to be grounded

    Do galvanized wire mesh cable trays need to be grounded

    Do wire mesh cable trays need to be grounded? Yes. However, while wire mesh trays offer mechanical and thermal advantages, proper grounding and bonding are critical to ensure electrical safety, NEC compliance, and long-term system reliability. Metallic cable tray systems can become energized under fault conditions, making an effective grounding. The flexibility and scalability of cable trays make them an ideal choice for environments where cable density and organization can significantly impact operational efficiency. Each multi-conductor cable with its individual EGC conductor. The base rule sounds simple, yet the real-world detail still trips experienced installers. It instructs us on how to construct them, where to locate them, and how to stuff them with wires without using too much.

    [PDF Version]
  • Does the optical module need to be configured separately

    Does the optical module need to be configured separately

    An optical module is a typically hot-pluggable optical transceiver used in high-bandwidth data communications applications. Optical modules typically have an electrical interface on the side that connects to the inside of the system and an optical interface on the side that connects to the outside world through a fiber optic cable. The form factor and electrical interface are often specified by an interested group using a (MSA). Optical modules can either plug into a front pa.


  • Do cable trays in the server room need to be grounded

    Do cable trays in the server room need to be grounded

    All metallic cable trays shall be grounded as required in Article 250. The EGC is the most important conductor in an electrical system as its function is electrical safety. This article provides a comprehensive framework that governs various aspects of cable tray installations, including the types of cables that are deemed acceptable for use, requirements for grounding and bonding, and stipulations regarding tray fill capacity. It involves connecting cable trays to the facility's grounding system, providing a low-impedance path for fault currents and protecting personnel. Power circuit grounding of cable trays is explained in CTI Technical Bulletins, Titles No.


More industry information