Industrial optical communication solutions from TOMOR
Custom networking and fiber solutions for industry

European Council Approves Measures To Standardise

Browse technical resources about industrial optical communication, fiber switches, Ethernet over fiber, and networking solutions.

  • European Standard Cable Tray Elbow

    European Standard Cable Tray Elbow

    IEC 61537:2023 specifies requirements and tests for cable tray systems and cable ladder systems intended for the support and accommodation of cables and possibly other electrical equipment in electrical and/or communication systems installations. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned in this technical guide only apply to our own cable management ranges and cannot under any circumstances be transposed to similar or imitation products. LEGAL INFORMATION. Elbow 45° for cable tray, 100x100 mm, with unperforated side profiles, steel, pre-galvanised according to DIN EN 10346, incl. All fittings are available in sizes and types corresponding to the straight cable tray sections. These fitting are including: elbow, horizontal cross, vertical inside. Clear cable routing – Organized and safe cable management, easy maintenance, helps prevent failures. Fast installation – Reduce installation costs with quick and efficient.

    [PDF Version]
  • Optical power meter measures light intensity value

    Optical power meter measures light intensity value

    An optical power meter detects and measures the intensity of light in a fiber. The readings determine whether the network is functioning properly or experiencing excessive loss. It details the main components, including sensor heads and display units, and explains the two primary sensor technologies: robust thermal sensors for high powers and. These meters provide a precise and reliable method for quantifying the power level of light across various wavelengths, making them essential instruments in the testing and calibration of optical systems. It helps engineers verify the performance of optical fiber systems, ensuring that the signal strength meets requirements, and is an essential tool for communication network maintenance and troubleshooting.


  • Dust prevention measures for beam splitters

    Dust prevention measures for beam splitters

    These are physical methods designed to eliminate or minimize dust at its source: Water Suppression Systems: Use water sprays to reduce dust during tasks like drilling or cutting. Ventilation Systems: Install local exhaust ventilation (LEV) to capture airborne particles before they. Dust arises in nearly all phases of demolition, strip-out and cutting of mineral and metallic materials. Especially when working with concrete demolition. Hydraulic tools from Darda GmbH – such as concrete demolition shears or rock and concrete splitters – are often used where precise, controlled, and ideally lower-dust methods are required. It provides an expert-curated supplier directory, buyer-focused technical background information, and structured selection criteria to support professional procurement decisions. What are Beam Dumps? There are various situations. 📦 For purchasing, use the RP Photonics Buyer's Guide for beam splitters. Construction sites can have large areas of soil disturbance and open space from which wind can pick up dust particles. In Industries handling combustible dust, the stakes are even higher, as poor management can lead to catastrophic explosions.

    [PDF Version]
  • Measures to be taken for exposed wires in distribution boxes

    Measures to be taken for exposed wires in distribution boxes

    Comprehensive guide to handling exposed wires: immediate safety protocol, voltage diagnosis, temporary securing, and permanent, code-compliant repair limits. This section applies to work on exposed live parts, or near enough to them to expose the employee to any hazard they present. General - Qualified employees only. Only qualified employees may work in areas. The first step is to de-energize the exposed wire to eliminate the immediate threat of electrocution. Locate the electrical service panel, often called the breaker box, and turn off the corresponding circuit breaker. Exposed electrical wiring — whether from damaged cable insulation, a rodent chew, a renovation mishap, or aged wiring — is a shock hazard and a fire hazard. This requires professional repair. Both the Occupational Safety and Health Administration (OSHA) and the National Fire Protection. Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +49 69 2381 5497
Address Am Hauptbahnhof 10, 60329 Frankfurt am Main, Germany

Send an Inquiry