Industrial optical communication solutions from TOMOR
Custom networking and fiber solutions for industry

Corner Joint Welding All You Need To Know

Browse technical resources about industrial optical communication, fiber switches, Ethernet over fiber, and networking solutions.

  • Do data center PDUs need lightning protection

    Do data center PDUs need lightning protection

    If your equipment is sensitive to voltage fluctuations or installed in environments exposed to lightning, switching surges, or industrial electrical interference, a PDU with surge protection is recommended. Especially in data centers, lightning protection PDUs are a key tool to ensure stable operation of equipment. Data centres form the backbone of our digital infrastructure, yet they face significant risks from lightning strikes and power surges. In the Netherlands alone, around 300,000 lightning strikes are recorded. Many data center managers assume that power distribution units (PDUs), especially rack-mounted PDUs, automatically protect servers from voltage spikes. A single lightning strike or utility power surge can damage critical equipment, disrupt operations, and lead to. Based on the principle that 'prevention is better than cure' it is advisable to think about the protection of your data centre against the risk of lightning strikes.

    [PDF Version]
  • Do relay protection systems need to be calibrated annually

    Do relay protection systems need to be calibrated annually

    110 (4), ER (Electricity Regulations) 1994; any protective relay and device of an installation will need to be checked, tested and calibrated by a competent person at least once every two years, or at any time as directed by the Energy Commission. Why is protective relay testing. Settings of various relays need co-ordination. Tests are conducted by the manufacturer at manufacturer s works, and by the user at site during commissioning and periodic maintenance. Many operators carry out secondary injection annually to ensure relays that protect circuits against overloads or faults operate appropriately. If applicable, documentation is required detailing how verified protection segments overlap to ensure there is not a gap. A relay may only need to operate for a fraction of a second in its decades-long life, but that moment can prevent extensive damage, prolonged outages, and worker injury.

    [PDF Version]
  • Does the Xiaomi 10 Gigabit switch need a fiber optic port

    Does the Xiaomi 10 Gigabit switch need a fiber optic port

    The Xiaomi 10G switch is equipped with dual 10G SFP+ network ports and self-purchased optical and electrical modules, supporting a maximum transmission rate of 10G and a total forwarding capacity of 60Gbps. The 10G switch is equipped with 4 2. 5G network ports, supports multiple speeds of. The Xiaomi Mi 10 Gigabit Ethernet Switch offers 4x2. 5G ports with 10Gbps aggregate bandwidth, ideal for multi-device setups, though it lacks VLAN support and acts as a basic Layer 2 unmanaged switch suitable for extending LAN connectivity. 5GB ports for an up to " dual LAN and dual WAN " network. It can do so with a choice between a 10Gb RJ-45 or a 10Gb SFP+ port. It facilitates the routing of data traffic between devices in a network, ensuring efficient communication over copper ports within a network.

    [PDF Version]
  • Do horizontal cable trays need cover plates

    Do horizontal cable trays need cover plates

    Due to their exposure to the open air because of the cable trays, the wires contained within need a very durable outer covering. The regulations dictate that the cables must either be Type TC (also known as Tray Rated) or must be metal-armored (Type MC). Here's what you need to know: Cable Types: Only use. The short answer is no. These essential components: Example:. This guide covers the critical steps, from selecting the right electrical cable tray and performing accurate cable fill calculations to managing a safe cable pull through and ensuring all bonding and grounding requirements are met. For licensed electricians, mastering these principles is essential. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions.

    [PDF Version]
  • Do galvanized wire mesh cable trays need to be grounded

    Do galvanized wire mesh cable trays need to be grounded

    Do wire mesh cable trays need to be grounded? Yes. However, while wire mesh trays offer mechanical and thermal advantages, proper grounding and bonding are critical to ensure electrical safety, NEC compliance, and long-term system reliability. Metallic cable tray systems can become energized under fault conditions, making an effective grounding. The flexibility and scalability of cable trays make them an ideal choice for environments where cable density and organization can significantly impact operational efficiency. Each multi-conductor cable with its individual EGC conductor. The base rule sounds simple, yet the real-world detail still trips experienced installers. It instructs us on how to construct them, where to locate them, and how to stuff them with wires without using too much.

    [PDF Version]
  • Does the optical module need to be configured separately

    Does the optical module need to be configured separately

    An optical module is a typically hot-pluggable optical transceiver used in high-bandwidth data communications applications. Optical modules typically have an electrical interface on the side that connects to the inside of the system and an optical interface on the side that connects to the outside world through a fiber optic cable. The form factor and electrical interface are often specified by an interested group using a (MSA). Optical modules can either plug into a front pa.


  • Does Gyts fiber optic cable need to be grounded

    Does Gyts fiber optic cable need to be grounded

    Steel‑armored cables (GYTS and GYTA53) must be grounded at both ends to prevent lightning‑induced current. Ungrounded armor acts as an antenna and will destroy sensitive SFP modules. Sharp bends inside handholes are the #1 cause of field‑repaired links. These cables include metallic components that can carry electrical currents, presenting potential hazards such as electrical shock or fire. This Applications Engineering Note (AE Note) discusses conventional bonding and grounding practices for conductive fiber optic cable and hardware installations within the scope of the National Electrical Code (NEC). This AE Note does not address outside plant fiber optic installations or. “What needs to be grounded in a fiber optic network?” The standard answer of “everything” seemed illogical and was unsatisfactory to him. In installations where an optical fiber cable is exposed to contact with electric light or power conductors and the cable enters the building, the. GYTS Fiber Optic Cable is the outdoor fiber optic cable type used for duct and aerial applications. A related GYTA type cable is available.

    [PDF Version]
  • Need to buy a distribution box

    Need to buy a distribution box

    When selecting a distribution box electrical for residential or commercial use, prioritize models with UL certification, adequate circuit capacity, and corrosion-resistant enclosures. The right choice depends on your load requirements, environmental conditions, and compliance needs. A well-chosen electrical distribution box ensures efficient circuit management, protects against overloads, and supports future. A distribution box is a low-voltage electrical enclosure that receives incoming power and distributes it safely to multiple outgoing circuits through protective and switching devices such as MCBs, RCDs, RCBOs, fuses, isolators, busbars, neutral bars, earth bars, and surge protective devices. But how do you choose the right one for your application? In this article, we break down the key types, core functions, and selection tips to help you make an. A home distribution box should match your circuit count, rated current, safety rules, and future power needs. A good choice has enough spare ways, suitable RCD or RCBO protection, surge protection where needed, and an enclosure approved for the local installation standard.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +49 69 2381 5497
Address Am Hauptbahnhof 10, 60329 Frankfurt am Main, Germany

Send an Inquiry